<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-01 15-17-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.30 MHz 3/5, 75 dBuV MPB R1
Pilot RDS Phase Difference
6.6 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 26 kHz 519 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,9 dBr 5,20 dBr 7,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" MPB R1 " 2491 10 (Pop M) 0 1 1 13 15:17, 1.09.2026
RT
"Let The Music - Prospa "
AF EON
92.2, 97.4, 98.2, 99.7, 103.3, 106.7 MHz D3A3, D210, D220, 43E1
FM Scope Max at: 26 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2026.09.01 15.16.25 Total samples: 519 Equivalent time: 0:00:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 10 20 30
FM Scope MAX: 7,1 dBr MIN: 2,9 dBr AVE: 5,20 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2026.09.01 15.16.24) 15.02 15.04 15.06 15.08 15.10 15.12 15.14 15.16 0 2 4 6 8 Pm [dBr]